Model KFR80 Series Sprinklers
-
RASCOFLEX™ Sprinkler Connections
RASCOFLEX™ Brochure
RASCOFLEX™ Installation Instructions
RASCOFLEX™ Bulletin 213
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR Series
Bulletin 014
Style:
Upright, Pendent, Conventional, Recessed Pendent, Vertical Sidewall, Horizontal Sidewall, Recessed HSW, Concealed Pendent (CCP)
K-Factor:
2.8 (40), 4.0 (57), 4.2 (60), 5.6 (80)
- BIM
- F1FR56C0W.rfa
- F1FR56C1C.rfa
- F1FR56C1W.rfa
- F1FR56C5W.rfa
- F1FR56H0C.rfa
- F1FR56H1B.rfa
- F1FR56P0C.rfa
- F1FR56P0B.rfa
- F1FR56H0W.rfa
- F1FR56H1C.rfa
- F1FR56H1W.rfa
- F1FR56H2B.rfa
- F1FR56H2C.rfa
- F1FR56H2W.rfa
- F1FR56P0W.rfa
- F1FR56P1B.rfa
- F1FR56P1C.rfa
- F1FR56P1W.rfa
- F1FR56P2B.rfa
- F1FR56P2C.rfa
- F1FR56P2W.rfa
- F1FR56P3B.rfa
- F1FR56P3C.rfa
- F1FR56U0B.rfa
- F1FR56U1B.rfa
- F1FR56U1C.rfa
- F1FR56U1W.rfa
- F1FR56U2B.rfa
- F1FR56U3B.rfa
- F1FR56U5B.rfa
- F1FR56V1B.rfa
- F1FR56V1C.rfa
- F1FR56V1W.rfa
- F1FR56H3B.rfa
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Model KFR56 Series Sprinklers
Bulletin 036
Style:
Upright, Recessed Pendent, Horizontal Sidewall, Recessed Horizontal Sidewall, Conical Concealed, Pendent
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Model G5 Series
Bulletin 034
Style:
Flat Concealed
K-Factor:
2.8 (40), 4.2 (60), 5.6 (80), 8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR-SS Series Stainless Steel Sprinklers
Bulletin 065
Style:
Upright, Pendent, Recessed Pendent
K-Factor:
5.6 (80), 8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1-SS Series Stainless Steel Sprinklers
Bulletin 064
Style:
Upright, Pendent, Recessed Pendent
K-Factor:
5.6 (80), 8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR56-300
Bulletin 026
Style:
Pendent, Upright, Recessed Pendent, Horizontal Sidewall, Concealed Pendent (CCP), Recessed HSW, SWC56 Sidewall Concealed
K-Factor:
5.6 (80)
- BIM
- SWH0B.rfa
- SWH0C.rfa
- SWH0W.rfa
- SWH1B.rfa
- SWH1C.rfa
- SWH1W.rfa
- F1FR56P0B3.rfa
- F1FR56P0C3.rfa
- F1FR56P0W3.rfa
- F1FR56P1C3.rfa
- F1FR56P1B3.rfa
- F1FR56P1C3.rfa
- F1FR56P1W3.rfa
- F1FR56P2B3.rfa
- F1FR56P2C3.rfa
- F1FR56P2W3.rfa
- F1FR56P3B.rfa
- F1FR56P3B3.rfa
- F1FR56P3C3.rfa
- F1FR56P3W3.rfa
- F1FR56P5B3.rfa
- F1FR56P5C3.rfa
- F1FR56P5W3.rfa
- F1FR56U0B3.rfa
- F1FR56U0C3.rfa
- F1FR56U0W3.rfa
- F1FR56U1B3.rfa
- F1FR56U1C3.rfa
- F1FR56U1W3.rfa
- F1FR56U2B3.rfa
- F1FR56U2C3.rfa
- F1FR56U2W3.rfa
- F1FR56U3B3.rfa
- F1FR56U3C3.rfa
- F1FR56U3W3.rfa
- F1FR56U5B3.rfa
- F1FR56U5C3.rfa
- F1FR56U5W3.rfa
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR LO
Bulletin 136
Style:
Upright, Pendent, Conventional, Recessed Pendent
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR-300
Bulletin 156 Rev D
Style:
Upright, Pendent, Recessed Pendent
K-Factor:
8.0 (115)
- BIM
- F1FRP0LB3.rfa
- F1FRP0LC3.rfa
- F1FRP0LW3.rfa
- F1FRP1LB3.rfa
- F1FRP1LC3.rfa
- F1FRP1LW3.rfa
- F1FRP2LB3.rfa
- F1FRP2LC3.rfa
- F1FRP2LW3.rfa
- F1FRP3LB3.rfa
- F1FRP3LC3.rfa
- F1FRP3LW3.rfa
- F1FRP5LB3.rfa
- F1FRU5LC3.rfa
- F1FRP5LW3.rfa
- F1FRU0LB3.rfa
- F1FRU0LC3.rfa
- F1FRU0LW3.rfa
- F1FRP2LB3.rfa
- F1FRU2LW3.rfa
- F1FRU3LB3.rfa
- F1FRU2LC3.rfa
- F1FRU2LW3.rfa
- F1FRU3LB3.rfa
- F1FRU3LC3.rfa
- F1FRU3LW3.rfa
- F1FRU5LB3.rfa
- F1FRU5LC3.rfa
- F1FRU5LW3.rfa
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR LO Large Orifice (International)
Bulletin 038 Rev C
Style:
Upright, Pendent, Recessed Pendent
K-Factor:
115 metric (8.0 US)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
KFR56-300
Bulletin 039
Style:
Upright, Horizontal Sidewall, Recessed Pendent, Pendent, Recessed Horizontal Sidewall, Conical Concealed
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Model J112SS Stainless Steel Series Sprinklers
Bulletin 178
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
G, G/F1 Recessed
Bulletin 112 Rev X
Style:
Vertical Sidewall-Upright, Vertical Sidewall-Pendent, Horizontal Sidewall, Recessed Horizontal Sidewall, EC Horizontal Sidewall, Recessed Extended Coverage Sidewall
K-Factor:
2.82 (40.6), 4.24 (61), 5.6 (80), 7.96 (114.7), 8.2 (118.2)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
XL Commercial Flush Series
Bulletin 145
Style:
Flush Style Pendent, Horizontal Sidewall
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
JL112 and J112 Upright, Pendent, & Recessed
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1 Series
Bulletin 013
Style:
Upright, Pendent, Conventional, Recessed Pendent, Vertical Sidewall, Horizontal Sidewall, Recessed HSW
K-Factor:
2.8 (40), 4.2 (60), 5.6 (80)
- BIM
- F56C1B.rfa
- F56C1C.rfa
- F56C1W.rfa
- F56C2B.rfa
- F56C5B.rfa
- F56H1B.rfa
- F56H1C.rfa
- F56H1W.rfa
- F56H2B.rfa
- F56H2C.rfa
- F56H2W.rfa
- F56P0B.rfa
- F56P0C.rfa
- F56P1B.rfa
- F56P1C.rfa
- F56P2B.rfa
- F56P2C.rfa
- F56P2W.rfa
- F56P3B.rfa
- F56P3C.rfa
- F56P5B.rfa
- F56P5C.rfa
- F56P6B.rfa
- F56U0B.rfa
- F56U1B.rfa
- F56U1C.rfa
- F56U2B.rfa
- F56U3B.rfa
- F56U5B.rfa
- F56V1B.rfa
- F56V1C.rfa
- F56V1W.rfa
- F56P0B3.rfa
- F56P0C3.rfa
- F56P1B3.rfa
- F56P1C3.rfa
- F56P1W.rfa
- F56P1W3.rfa
- F56P2B3.rfa
- F56P2C3.rfa
- F56P1W3.rfa
- F56P3B3.rfa
- F56P3C3.rfa
- F56P5B3.rfa
- F56P5C3.rfa
- F56U0B3.rfa
- F56U1B3.rfa
- F56U1C3.rfa
- F56U2B3.rfa
- F56U3B3.rfa
- F56U5B3.rfa
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR56 QREC
Bulletin 028
Style:
Pendent, Recessed Pendent, Concealed Pendent, Recessed HSW EC-8, HSW EC-8
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR QREC
Bulletin 148 Rev H
Style:
Pendent, Recessed Pendent, Recessed HSW EC-9, HSW EC-9
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR56-300 QREC
Bulletin 030 Rev C
Style:
Pendent, Recessed Pendent, Conical Concealed (CCP)
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR-300 QREC
Bulletin 159 Rev E
Style:
Pendent, Horizontal Sidewall, Recessed Pendent, Recessed Horizontal Sidewall
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
DH56
Bulletin 015
Style:
Concealed Horizontal Sidewall (SWC), Horizontal Sidewall, Horizontal Sidewall Recessed
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F156-300
Bulletin 025 Rev D
Style:
Upright, Pendent, Recessed Pendent
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
DH80
Bulletin 003 Rev F
Style:
Horizontal Sidewall, Recessed Horizontal Sidewall, Concealed Horizontal Sidewall (SWC)
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1 LO
Bulletin 117
Style:
Upright, Pendent, EC Pendent, Conventional, Recessed Pendent, Recessed EC Pendent
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Model G Automatic Sprinklers
Bulletin 110
Style:
Upright, Pendent, Conventional
K-Factor:
1.98 (28.5), 2.82 (40.6), 4.10 (59.1), 4.24 (61), 5.62 (81.0), 7.96 (114.7), 8.20 (118.2)
- BIM
- GC1B.rfa
- GC1C.rfa
- GC2B.rfa
- GP13B.rfa
- GP13C.rfa
- GP17B.rfa
- GP17C.rfa
- GP1B.rfa
- GP1C.rfa
- GP1LB.rfa
- GP1LC.rfa
- GP1W.rfa
- GP27B.rfa
- GP2B.rfa
- GP2C.rfa
- GP2LB.rfa
- GP2LC.rfa
- GP3B.rfa
- GP3C.rfa
- GP3LB.rfa
- GP3LC.rfa
- GU13B.rfa
- GU17B.rfa
- GU1B.rfa
- GU1C.rfa
- GU1LB.rfa
- GU1LHB.rfa
- GU27B.rfa
- GU2B.rfa
- GU2LB.rfa
- GU2LHB.rfa
- GU3B.rfa
- GU3C.rfa
- GU3LB.rfa
- GU3LHB.rfa
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
SWC
Bulletin 163 Rev G
Style:
Conical Concealed Horizontal Sidewall (CCP)
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F3QR56 Dry
Bulletin 157
Style:
Pendent, Recessed Pendent, Horizontal Sidewall, Recessed Horizontal Sidewall, Conical Concealed (CCP), Upright
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
G Recessed
Bulletin 111 Rev O
Style:
Recessed Pendent
K-Factor:
2.75 (39.2), 2.82 (40.6), 4.24 (61), 5.53 (79.7), 5.6 (80), 7.96 (114.7)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F3QR80 Dry
Bulletin 061
Style:
Pendent, Recessed Pendent, Conical Concealed (CCP), Horizontal Sidewall, Recessed Horizontal Sidewall
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
G/F1
Bulletin 120
Style:
Recessed Pendent
K-Factor:
2.8 (40), 4.2 (60), 5.6 (80), 8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
DH56 Dry
Bulletin 016
Style:
Horizontal Sidewall, Recessed Horizontal Sidewall, Concealed Horizontal Sidewall (SWC)
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Model G4 Concealed
Bulletin 121
Style:
Flat Concealed
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
DH80 Dry
Bulletin 055
Style:
Horizontal Sidewall, Recessed Horizontal Sidewall, Concealed Horizontal Sidewall (SWC)
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Model G4-300 Concealed
Bulletin 161
Style:
Flat Concealed
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1-300
Bulletin 155 Rev E
Style:
Upright, Pendent, Recessed Pendent
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F3-56 Dry
Bulletin 153
Style:
Pendent, Recessed Pendent, Horizontal Sidewall, Recessed Horizontal Sidewall, Conical Concealed (CCP), Upright
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F3-80 Dry
Bulletin 060
Style:
Pendent, Recessed Pendent, Conical Concealed (CCP), Horizontal Sidewall, Recessed Horizontal Sidewall
K-Factor:
8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1Res Series Residential Sprinklers
Bulletin 135
Style:
Pendent, Horizontal Sidewall
K-Factor:
3.0 (43), 4.4 (63), 4.9 (71) , 5.8 (84), 7.6 (109)
:
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1Res LL Series Low Lead Residential Sprinklers
Bulletin 033
Style:
Pendent, Horizontal Sidewall
K-Factor:
3.0 (43), 4.4 (63), 4.9 (71) , 5.8 (84)
:
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
KFR-CCS 56 Combustible Concealed Space Sprinkler
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
LT56 Series Hallway and Corridor Sprinklers
Bulletin 058
Style:
Pendent, Recessed Pendent, Conical Concealed (CCP), Concealed
K-Factor:
5.6 (80)
:
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
RFC Series Residential Sprinklers
Bulletin 006
Style:
Pendent
K-Factor:
3.0 (43), 4.3 (62), 4.9 (71), 5.8 (84), 7.6 (109)
:
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
XL Series Institutional Sprinklers
Bulletin 113
Style:
Pendent, Horizontal Sidewall, EC Pendent, EC Horizontal Sidewall
K-Factor:
5.6 (80)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
GFR
Bulletin 131
Style:
Upright, Pendent, Horizontal Sidewall, Intermediate Level Upright, Intermediate Level Pendent Conventional, Recessed Pendent, Recessed Horizontal Sidewall
K-Factor:
2.8 (40), 4.2 (60), 5.6 (80), 8.0 (115)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
HV Spray Nozzles
Bulletin 105 Rev D
Finish:
Brass, Chrome Plated
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR-FS56, F1FR-FS42 Flat Spray (International)
Bulletin 022 Rev B
Style:
Pendent, Pendent with shield
K-Factor:
80 metric (5.6 US), 57 metric (4.2 US)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
KRes Series Residential Sprinklers
Bulletin 935
Style:
Pendent, Horizontal Sidewall
K-Factor:
3.0 (43), 4.4 (63), 4.9 (71), 5.8 (84)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Open Sprinklers
Bulletin 104 Rev R
Finish:
Bronze, Lead Plated, Wax Coated, Wax Coated over Lead Plated
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1S5-FS56, F1S5-FS42 Flat Spray (International)
Bulletin 023 Rev A
Style:
Pendent, Pendent with shield
K-Factor:
80 metric (5.6 US), 57 metric (4.2 US),
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
B, FM Spray Nozzles
Bulletin 103 Rev B
Finish:
Bronze, Chrome, Lead
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1S5 Standard Spray (International)
Bulletin 024 Rev A
Style:
Upright, Pendent, Conventional, Recessed Pendent
K-Factor:
80 metric (5.6 US)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
A Spray Nozzle
Bulletin 106 Rev H
Finish:
Bronze, Chrome, Lead
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1FR-FS LO Flat Spray (International)
Bulletin 037 Rev B
Style:
Pendent, Pendent with shield
K-Factor:
115 metric (8.0 US)
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
F1-FTR Pilot Line Detector
Bulletin 180
Style:
Pendent, Upright
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
FT Recessed Escutcheons (International)
Bulletin 210
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Sprinkler Guards and Water Shields
Bulletin 208
- CAD drawings
- C-1 Guard
- C-2 Guard
- C-3 Guard
- C-5 Guard
- D-1 Guard
- D-3 Guard
- D-4 Guard
- D-5 Guard
- D-6 Guard
- D-7 Guard
- D-8 Guard
- D-9 Guard
- E Water Shield
- S Water Shield
- K-22 Guard
- K-25 Guard
- K-22 Guard with S-5 Water Shield
- K-25 Guard with S-5 Water Shield
- F-1 Guard
- F-2 Guard
- F-3 Guard and Water Shield
- F-4 Guard
- F-5 Guard and Water Shield
- F-6 Guard and Water Shield
- F-7 Guard
- F-8 Guard and Water Shield
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Disclaimer
Distribution Patterns:
- The distribution patterns are provided to illustrate the approximate water spray trajectories for various Reliable sprinklers at pressures of 7, 15 and 30 psi, unless otherwise noted. However, it must be emphasized that Reliable sprinklers must be installed according to the pertinent National and Local Fire Codes, Standards and Installation Rules, all of which are considered to be minimum requirements for sprinkler system installations. If Reliable's sprinklers are not installed accordingly, the listing, approvals and warranties are not valid.
- The minimum requirements for water distribution from sprinklers (i.e., densities, areas of coverage, horizontal and vertical obstructions) are primarily provided in National Standards. These are the requirements that must be satisfied when designing sprinkler placements; whereas, the following distribution profile patterns are only for information.
- For our Residential Sprinklers Wall Wetting Patterns, please refer to Bulletin 007.
-
Commercial Basic
Distribution Patterns:
- Model F156 & F1FR56 Upright Sprinklers (SSU), 5.6 K-Factor
- Model F156 & F1FR56 Pendent Sprinklers (SSP), 5.6 K-Factor
- Model F156 & F1FR56 Horizontal Sidewall Sprinklers, 1/2” Orifice, HSW1 Deflector
- Model F1 & F1FR Upright Sprinklers (SSU), 3/8", 7/16", 1/2" & 17/32" Orifice Sizes
- Model F1 & F1FR Pendent Sprinklers (SSP), 3/8", 7/16", 1/2" & 17/32" Orifice Sizes
- Model F1 & F1FR Recessed Pendent Sprinklers, 3/8", 7/16", & 1/2" Orifice Sizes
- Model F1 & F1FR Vertical Sidewall Sprinklers, Upright & Pendent, 1/2" Orifice
- Model F1 & F1FR Conventional Sprinklers
- Model Flat Spray Sprinkler, K5.6 (K80 metric) & K8.0 (K115 metric)
- Model G & GFR Sprinklers, Upright (SSU) & Pendent (SSP), ½” & 17/32” Orifice Sizes
- Model G & GFR Sprinklers, Upright (SSU) & Pendent (SSP), 5/16”, 3/8” & 7/16” Orifice Sizes
- Model G & GFR Sprinklers Upright & Pendent, 10mm Orifice
- Model G & GFR Vertical Sidewall Sprinklers, 17/32” Orifice
- Model G & GFR Vertical Sidewall Sprinklers, ½” Orifice
- Model G & GFR Vertical Sidewall Sprinklers, 7/16” Orifice
- Model G & GFR Vertical Sidewall Sprinklers, 3/8” Orifice
- Model G & GFR Horizontal Sidewall Sprinklers, 17/32” Orifice, HSW1 Deflector
- Model G & GFR Horizontal Sidewall Sprinklers, ½” Orifice, HSW1 Deflector
- Model G & GFR Horizontal Sidewall Sprinklers, 7/16” Orifice, HSW1 Deflector
- Model G & GFR Horizontal Sidewall Sprinklers, 3/8” Orifice, HSW1 Deflector
- Model G & GFR Conventional Sprinklers, Upright & Pendent, 10, 15 & 20mm Orifice Sizes
- Model G Recessed Pendent Sprinklers, 3/8”, 7/16” & ½” Orifice Sizes
-
Commercial Decorative
Distribution Patterns:
- Model G6-56 Standard Spray Horizontal Sidewall Sprinkler, 1/2” Orifice
- Model G5 Concealed Sprinklers, 2.8, 4.2, 5.6 & 8.0 K-Factor
- Model G4, G4FR & G4A Concealed Sprinklers, 3/8”, 7/16”, 1/2" Orifice Sizes
- Model F4FR Concealed Sprinklers, 2.8, 4.2 & 5.6 K-Factor
- Model G1 Concealed Sprinklers, 3/8", 7/16", & 1/2" Orifice Sizes
- Model G4XLO QREC Concealed Sprinklers
-
Commercial Extended Coverage
Distribution Patterns:
- Model G6-80 Concealed QR EC Horizontal Sidewall Sprinkler, 17/32” Orifice
- Model JL112 & J112 ECOH/ECLH - Pendent
- Model JL112 & J112 ECOH/ECLH - Upright
- Model F1FR56 EC HSW 1/2” Orifice, EC8 Deflector
- Model F1FR Extended Coverage Horizontal Sidewall Sprinklers, 17/32” Orifice, EC9 Deflector
- Model F1 & F1FR Extended Coverage Pendent & Recessed Pendent Sprinklers, 1/2” & 17/32” Orifice, EC Deflector
- Model DH56 Extended Coverage Sprinklers, ½” Orifice
- Model DH80 Extended Coverage Sprinklers, 17/32” Orifice
- Model G Extended Coverage Horizontal Sidewall Sprinklers, 17/32” Orifice, EC4 Deflector
- Model G & GFR Extended Coverage Horizontal Sidewall Sprinkler, 1/2" Orifice, EC4 Deflector
- Model G4XLO QREC Concealed Sprinklers
- Model GFR VELO ECOH Pendent & Recessed Sprinklers (.15 density)
- Model G VELO ECOH Pendent & Recessed Pendent Sprinklers (.20 density)
- Model GFR VELO ECOH Upright Sprinklers (.15 density & .20 density)
- Model MBEC-14 Horizontal Sidewall Sprinklers
-
Commercial Dry
-
Storage
Distribution Patterns:
- Model JL-14 ESFR Pendent Sprinklers, 14 K-Factor
- Model JL-17 ESFR Pendent Sprinklers, 17 K-Factor
- Model HL-22 ESFR Pendent Sprinklers, 22 K-Factor
- Model G XLO Extra Large Orifice Upright Sprinklers – 0.64” Orifice
- Model J168 Standard Response Upright Sprinkler
- Model N252 EC Pendent, Recessed Pendent & Pendent for Control Mode Specific Application Sprinklers
- Model GL 112 Quick Response Upright Sprinkler
- Model GL 112 Quick Response Pendent Sprinkler
- Model G VELO Pendent Very Extra Large Orifice Sprinkler
- N25 ESFR Spray Pattern
WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov
-
Residential Sprinklers Wall Wetting Patterns
Bulletin 006 Rev L